Features:

This paragraph anesthesia machine adopts advanced and stable APL valve device, suitable for low flow anesthesia, color LCD screen, can display time pressure, flow time and pressure-volume loop, with oxygen concentration monitoring, and optional plug-in patient monitoring, composition anesthesia workstation.


Specifications:

Anesthesia ventilator 

 

Pneumatically driven electronically controlled system

Built-in ventilator, 10.4” LCD display

With 1 patient circuit for adult (Optional:patient circuit for children)

5-tube flowmeters, O2 & N2O & Air;0.1L/Min ~ 10 L/Min;

Two vaporizers,Enflurane/Isoflurane/Sevoflurane; (Optional: Halothane)

Oxygen Flush: 25~75 L/Min;

Respiration Mode: IPPV, SIPPV(VCV), IMV,SIMV, PEEP, Manu, Sigh

Tidal Volume: 0~1500 mL;

I:E: 8:1~1:10

Respiration Frequency: 1~99bpm;

PEEP: 1~10 hPa;

Ptr: -10~10 hPa;

CO2 absorber capacity: 1 kg

Lung compliance: ≤ 30mL/kPa;

IMV frequency: 1~12bpm

Inspiratory Plateau: 0~1S;

O2 Concentration: 21%~100%

Alarm parameter: upper /lower limit ofairway pressure, tidal volume exceed limitation, no tidal volume output, apnea,AC power malfunction, battery low power 


Patient Monitor

12.1''TFT large screen of high resolution

ECG: 5-lead, gain:×2.5mm/mV ×5.0mm/mV×10mm/mV ×20mm/mV, analysis of ST segment and abnormal of heart rate(anti-defibrillate, anti-HF    electrotome)  

Heart Rate: 20~250bpm  

RESP: Impedance, range: 0~100bpm

SpO2: 0%~100%  

Pulse Rate: 20~250bpm 

NIBP: SBP, DBP, MBP, 10~270mmHg interval ofautomatic measurement 1~90min adjustable 

TEMP: 0~50ºC

Alarm: Audio and visual alarm  

Tendency record 96 hours

 

Loop part: 

Integrated design, integrated breathingcircuit


Evaporator: 

High-precision double evaporators configuration, enflurane or isoflurane or Sevflurane or Haloflurane

Concentration adjustment range: 0.5 ~ 5%VOL

Evaporator flow, pressure, and automatictemperature compensation function

Self-locking feature


Configuration:

Vaporizer: Two vaporizers, Enflurane/Isoflurane/Sevoflurane(Option: Halothane)

Anesthesia gas concentration range: 0.5~5%

Soda lime absorption system: resistance tohigh temperature of 176 degrees Celsius.