Technical Specification:

Display

Screen Type: High-resolution display

Screen Size: 7 inch (17.7cm) diagonally 

Sweep Speed: 25mm/sec 

Information: Heart Rate, Lead/Pads, Alarm on/off, Sop2, AED Functions and Prompts, Alarm Selection and Limits, Delivered Energy.

Defibrillator

Waveform: Biphasic 

Energy Display: Monitor dispaly indicates both selected and delivered energy 

Charge Prompt Type: Voice and visual prompts. 

Electrode Impedance Measurement Range: 0-250 ohms.

ECG Monitoring

Patient Connection: 3-lead ECG cable, or 5-lead cable, paddles.

Lead Selection: Display on monitor, paddles, I, II, III, AVR, AVL, AVF, V, 

ECG Size: 0.25, 0.5, 1, 1.5, 2, 4cm/mV display on monitor 

Heart Rate: 20-300 BPM Heart Rate Alarm, On/Off displayed on monitor, user-selectable. 

Smart Alarms: Beeper/Voice prompts indicate shock able rhythm.

Battery

Type: Rechargeable, Ni-MH Battery, 12V.

Operating Time: For a new, fully charged battery, 60 defibrillator discharges at maximum energy, or 3 hours minimum of continuous ECG monitoring. Additional parameters will effect operating time with different functions.

SPO2 Module

Measurement Range: 30~100%, ±2% between 80%~90%, others ±5%

Alarm Range: User set high limit and low limit. 

Alarm Accuracy: ±10% within setting values. 

Alarm time Accuracy: less than 12 sec.

AED Mode

AED Function: Auto analyze and charge x3 with programmable auto energy level selection, screen prompts, and voice prompts.

Shockable Rhythms: Ventricular fibrillation                                    

                                 Ventricular tachycardia                                    

                                 QRS complex wave duration 

Charge Control: Control on device front panel, press key on paddle.

Manual Mode

Energy Selection: Selectable at 2, 5, 7, 10, 20, 30, 50, 70, 100, 150, 200, 300, 360 joules.

Synchronized Mode: Synchronizes defibrillator pulse to patient's R-wave. "SYNC" message displayed on monitor.