Get Quotes
Download Full Catalogue
Model: CNME011304
Technical Specification:
Physical
| Dimensions: 210 mm (w)x 286 mm (d)x 79.5 mm(h) Weight: Main unit (Pro): 2.9 kg(without battery) Main unit (Public):2.7 kg (without battery) Rechargeable battery:0.51 kg Disposable battery:0.42 kg |
Environmental
| Water Resistance: IP5x Solids Resistance: IP5x Temperature: Operating:0 to 50℃ Storage:-30 to 70℃ Humidity: Operating/Storage:0 to 95 %,non-condensation Altitude: Operating/Storage:-381 m to+4575 m Shock and Vibration: MIL-SID-810G,Method 516.6 MIL-STD-810G,Method 514.6 EN1789(Medical devices for use in road ambulances) Bump: EN1789(Medical devices for use in road ambulances) Free fall: EN1789(height of fall:0.75m) IEC60068-2-32(height of fall:1.5 m) Safety: EN/IEC 60601-1 |
Display
| Type: TFT Color LCD Dimensions: 7 inch Resolution: 800 x 480 pixels Display Waveforms: 1 channel Wave viewing Time: 6 s |
Power
| Rechargeable Battery( for Pro) Type: 3000 mAh, 14.8v rechargeable lithium ion battery pack Charge Time: Fully charged less than 3 hours, 90% charged less than 2 hours Capacity Indicator: 5-segment indicator for battery capacity evaluation Capacity (new fully charged battery):Minimum 300 times 200 J discharge or 200 times 360 J discharge Disposable Battery Type: Li/MnO2 Capacity (new fully charged battery): Minimum 300 times 200 J discharge or 200 times 360 J discharge (The same to rechargeable battery) Shelf Life: 5 years from date of manufacture Standby Life: 4 years |
Pads | Active Surface Area: 12.8"(83 cm²)each (adult) 6.7”(43 cm²) each(pediatric) Cable Length: 82.6",+4”(210 cm,+10 cm) Use-by Date: 36 months from date of manufacture(adult) 18 months from date of manufacture(pediatric) |
Data storage
| Events: Up to 1000 events Waveform Storage: Up to 8 hours of consecutive ECG waveform Voice Recording: Max.3 hours Data Export: Through USB flash memory |
Defibrillator
| Waveform: Biphasic truncated exponential waveform, with impedance compensation Energy Accuracy: ±2 Jor 15%, whichever is greater, Shock Delivery: Via multifunctional defibrillation electrode pads Patient lmpedance: 25 to 200 Ohm |
Manual Mode ( for Pro)
| Output Energy: 1,2,3,4,5,6,7,8,9,10,15,20,30,50,70,100,150,170, 200,300,360J Charge Time: Less than 5 seconds to 200 J with a new fully charged battery Less than 8 seconds to 360 J with a new fully charged battery Synchronous Cardioversion: Energy transfer begins within 60ms after the QRS peak |
AED Mode | Output energy: User configurable AED shock series: Energy level for adult: 100 to 360 J, configurable Energy level for pediatric: 10 to 100 J, configurable Shock series: 1,2,3, configurable Default configuration meets 2015AHA/ERC Guidelines Quick shock: Typically analyzes and charges in <8 seconds from the end of "Stop CPR" prompt |
ECG Monitoring ( for Pro )
| Lead Type: 3 leads ECG,PADS Lead Selection: l,ll,lll Pads Heart Rate Display: Adult:15 to 300 bpm Pediatric:15 to 350 bpm Resolution:1 bpm ECG Size: AUTO,1.25 mm/mV(x0.125),2.5 mm/mV(x0.25), 5 mm/mV(x0.5),10 mm/mV(x1),20 mm/mV(x2), 40 mm/mV(x4) Sweep Speed: 25 mm/s |
Automated and User-activated Self-tests
| Daily Auto Tests: Test internal circuitry, energy charging/delivery system, pads, and battery capacity Battery-insert/User Tests: Upon battery insertion, extensive auto self-tests and user-interactive test check device readiness Status Indicators: Blinking green light indicates ready for use.Blinking red light indicates or/ and audible beep indicates need for maintenance |