Home  >  Products  >  Emergency and Clinics Apparatuses  >  Defibrillator
Hospital Use Biphasic Defibrillator Monitor Machine
  • Hospital Use Biphasic Defibrillator Monitor Machine
Hospital Use Biphasic Defibrillator Monitor Machine

Get Quotes

Download Full Catalogue

Hospital Use Biphasic Defibrillator Monitor Machine

Model: CNME011302

Features:

CNME011302, a professional biphasic defibrillator-monitor, meets the requirements of medical professionals in hospitals and clinics worldwide. The compact, durable, and ergonomic design of CNME011302 makes it suitable for emergency use. Proven technologies ensure a robust unit, ready to be used in different environments. With different operation modes (manual defibrillation, AED, pacer, and monitoring mode) you are in control of any situation.

 

Key Features:

· 4-in-one design including: monitoring, Manual Defib, AED and pacer

· Power on within 2s, Charging to 200J within 3s, ECG recovery within 2.5s

· Up to 360J escalating dose energy to maximize defibrillation success

· Powerful power capacity with battery to support continuous long time monitoring and shocks during transport without external power supply

· Effective IT solution avoiding manual recording, improving efficiency and reducing the workload of clinical staff

 

Technical Specification

Physical

Dimensions:

Without external paddles: 295mm (w)x 218 mm (d) x 279 mm (h)

With external paddles: 295 mm (w) x 218 mm (d)x323 mm (h)

Weight:

Main unit:

5.6 kg (including ECG/ defibrillator/ pacing/5pO/ 2Temp/ Resp)

Battery package (each): 0.75 kg

External paddle sets: 0.8 kg

Environmental and Physical Requirements

Water Resistance: IPX4 (without external power)

Solids Resistance: IP4X

Temperature:

Operating: 0 to 45℃ (Microstream CO2:0 to 40℃; Sidestream CO2: 5to 35°C)

(at least 60 minutes of working time when the temperature reduces from room temperature to -20℃)

Humidity:

Operating/Storage: 10 to 95%, non-condensation

Altitude: Operating/ Storage: -381m to+4575m

Shock and Vibration:

Comply the requirements of21.102, IS09919 (Shock and vibration for transport}

Bump:

Comply the requirements of 6.3.4.2, EN1789(Medical devices for use in road ambulances)

Free fall: :

Comply the requirements of 6.3.4.3, EN1789 (Height of fall: 0.75 m)

EMC:

Comply IEC60601-1-2

Safety:

Comply EN/IEC 60601-1

Display

Type: TFT Color LCD

Dimensions: 8.4inch

Resolution: 800x600 pixels

Display Waveforms: Max.4 channels

Wave Viewing Time: Max.16s (ECG)

Power

AC Power

Line voltage: 100 to 240V~(±10%)

Current: 1.8 to 0.8A

Frequency: 50/60 Hz (±3 Hz)

DC Power (through DC-AC Inverter)

Input voltage: 12VDC

Power Consumption: 190W

Battery

Type: 4.5 Ah, 14.8V, recharge able lithium ion battery pack

Number: Max.2

Charge time: 2 hours to 90% and 3 hours to 100% with device off

Capacity Indicator:

5-segment led indicator for fast battery capacity evaluation

Capacity(Two new, fully charged bttery):

Monitoring Mode: ≥10hours, Without recording, typical ECG monitoring, LCD brightness set to 1

Defib Mode: 200 times, 360J discharge at intervals of 1 minute without recording

Pacing Mode: 6 hours, 50Ohm load im pedance, Pacing rate: 80bpm, Pacing output: 60mA

Defibrillator

Wavefom:

Biphasic truncated exponential waveform (BTE) with impedance compensation

Energy accuracy:

±2Jor 15% of setting, whichever is greater, into 50 Ohm

Charge Time:

Less than 5 seconds to 200Joules with a new, fully charged battery

Less than 8 seconds to 360Joules with a new, fully charged battery

Shock Delivery:

Via multifunction defib electrode pads, or paddles

Patient Impedance Range:

20 to 200 Ohm (External defibrillation)

Manual Mode

Output Energy:

1,234,5.6,7,8,9,10,15,20,30,50,70,100,150, 170,200,300,360J

Synchronous Cardioversion: Energy transfer begins within 60ms of the QRS peak

Energy transfer begins within 25ms of the External 5ync Pulse

AED Mode

Output Energy: Userselectable

AED Shock Series:

Energy level: 100 to 360 J, selectable

Shocks series:1, 2, 3, selectable

Default configuration meets 2010 AHA Guidelines

5ensitivity and Specificity: Meets AAMI DF -80

Noninvasive Pacing

Waveform: Mono phasic square wave pulse

Pulse Width: 20 ms, ±5%

Refractory period:

200to 300 ms, ±3% (function of rate)

Pacing Mode: Demand or fixed

Pacing rate: 40 ppm to 170ppm, ±1.5%

Pacing output:

0 mA to 200 mA, ±5% or 5mA, whichever is greater

4:1 pacing:

Pacing pulse frequency reduced by factor of 4 when activated

 

ECG Monitoring

 

Lead type:

3 leads ECG, 5leads ECG, 12leads ECG PADS/ PADDLES

Lead Selection:

3Head:l, ll, lll

5-lead: l, ll, lll, aVR, aVL, aVFV

12-lead: l, ll, lll, aVR, aVL, aVF, V1 to V6

Pads/Paddles

HeartRate Display:

Adult: 15 to300 bpm

Pediatric: 15 to 350 bpm

Neonate: 15 to 350bpm

Resolution: 1 bpm

Arrhymia: Yes

Alarms: Yes

ECG size:

2.5mm/mV(x0.25), 5mm/mV(x0.5), 10 mm/mV(x 1), 20 mm/mV(x2), 40m m/mW(x4)

Sweep speed:

6.25mm/s, 12.5 mm/s, 25 mm/s, 50mm/s

Patient Isolation (defibrillation proof):

Type CR: EG, RESP, TEMP, SpO2, NIBP, IBP

Type BF: CO2 and external defib

Respiration

 

Technique: Trans thoracic impedance

Range:

Adult:0 to 120 rpm

Pediatric, neonate:0 to 150 rpm

Resolution: 1rpm.

Spo2, Pulse Oximetry

 

SpO2

Range: 0 to 100%

Resolution: 1%

PR Range: 20 to 254 bpm

Masimo SpO2

Range: 1to100%.

Resolution: 1%

PR Range: 25 to 240bpm.

Nellcor SpO2

Range: 0 to 100%

Resolution: 1%

PR Range: 20 to 300 bpm



Ask for Quote Now

Download Our Fullcatalogue

Download Our Full Catalogue

Get notified about new products

chat online