Home  >  Products  >  Emergency and Clinics Apparatuses  >  Anesthesia Machine
Medical Apparatus 10.4 TFT Color Screen Anesthesia Machine/System
  • Medical Apparatus 10.4 TFT Color Screen Anesthesia Machine/System
Medical Apparatus 10.4 TFT Color Screen Anesthesia Machine/System

Get Quotes

Download Full Catalogue

Medical Apparatus 10.4 TFT Color Screen Anesthesia Machine/System

Model: CNME010306

Description:
PCV and SIMV+PS modes ensure flexibility in ventilation, machine doable for both pediatric and adult operation
Optional monitoring functions: CO2 and anesthetic gas
Flowmeter provides minimum 25% concentration of oxygen in O2 /N2O mixture
Breathing system easy to remove and clean, fully autoclavable, optional CO2 bypass
Enhances usability with auxiliary oxygen, suction, auxiliary power source, monitor arm, infusion pump etc.
CE marked, meets EU clinical requirement


Technical Specification:

Physical & Environment SpecificationsDimensions(W×H×D): 704mm × 1403mm × 750mm
Weight: 115kg (including trolley base and 2 vaporizers, without cylinder)
Operation Temperature: +10~+40°C
Operation Humidity: ≤80% (noncondensing)
Storage Temperature: -20~+55°C
Storage Humidity: ≤93% (noncondensing)
Electrical Specifications Mains: 100~240V AC, 50/60Hz
Battery: 24V DC, minimum 120 min
Outlets: 4 on back, 1.5A individual
Pneumatic Specifications Gas Supply: Air, O2, N2O; 280kPa ~ 600kPa
Flowmeters: O2  Range: 0~1L/min; 1~10L/min
N2O Range: 0~1L/min; 1~10L/min Air Range: 0~1L/min; 1~12L/min Auxiliary O2 Range: 0 ~15 L/min
Flowmeter backlight
Gas System: Oxygen supply failure alarm
N2O-cut-off system
O2 flush: 25~75L/min
ACGO: Optional auxiliary common gas outlet
AGSS: Optional anesthetic gas scavenging system
Breathing System Specifications Operational Modes: Closed, Semi-closed, Semi- open
CO2 Canister: 2 Loose fill (3L) or 2 prepacks,
optional single canister (1.8 L)
APL Range: Spontaneous breathing (SP) - 70 cmH2O
Material: Autoclavable (except O2 cell and mechanical pressure gauge)
CO2 bypass: Optional
Ventilator Specifications

Driven Mode: Pneumatically driven and electronically controlled
Patient Types: Adult, Pediatric
Ventilation Modes: IPPV, PCV, SIMV+PS, PS and Manual
Setting Modes: Touch key & navigator wheel knob
Tidal Volume: 20~1500ml
Ventilation Frequency: 4~100bpm
I:E Ratio: 4:1~1:8
Pressure (inspired) Range: 5~70cmH2O
Pressure (support) Range: 3~50cmH2O
PEEP: Off,3~30 cmH2O
Tslope: 0~2s
Inspiratory Plateau: Off, 5%~60%Ti
Trigger Sensitivity: 1~15L/min
Compensation: Compliance and leakage compensation, fresh gas compensation and altitude compensation
Ventilator MonitoringDisplay: 10.4" TFT color screen
Pressure: Ppeak, Pplat, Pmean, PEEP
Volumes: MV, Vt, Freq
Gas: O2 Concentration, optional CO2, Agent and MAC
Graph Display: P-t, F-t, P-V, F-V loops(can be saved), optional CO2-t
Alarm: High Airway Pressure/Low Airway Pressure
Sustained airway pressure
High Minute Volume/Low Minute Volume
High FiO2/Low FiO2
High Breath Rate
O2 Supply failure
Power failure
Apnea Alarm
Alarm Silence: 110 seconds
 Vaporizer Support two vaporizers
Agent: Halothane, Enflurane, Isoflurane, Sevoflurane
Installation Mode: Selectatec with interlock,
optional standby vaporizer parking holder
Filling Type: Pour Fill, Key Fill, Quik-Fil


Ask for Quote Now

Download Our Fullcatalogue

Download Our Full Catalogue

Get notified about new products

chat online