Get Quotes
Download Full Catalogue
Model: CNME011216
Description:
Outlook:
Touch Screen, more intuitionistic display
12.1 inch color LCD, 12 waveforms synchronously display
Portable, overturning & folding design
QWERTY keyboard design, multi-function shortcut key,
easy for operation
IPX1 waterproof performance
Data Saving:
Support saving internal data
Support saving High-capacity data via built-in SD card
Support saving data via U dish
Support data transferring & reviewing & reanalyzing
Improved Performance:
Adapt Innovative digital filters for better performance
Fast-speed baseline correction algorithm rapidly stabilize
baseline
Adapt 24-bit high-resolution data sampling
Adapt 1000Hz high- frequency data sampling
24-bit high-accuracy data saving ensure the accuracy of
follow-up data analysis
Synchronization analysis for 12 lead waveforms, supporting
report preview & report format adjustment
Function Upgrade:
Automatic measurement and interpretation certified
by CSE database
Rhythm report realized synchronous display of multi-channel data
Support Pre-sampling mode, Real-time sampling mode and
Trigger sampling mode
Automatic energy saving function
Support folded & reel type thermosensitive printing paper
Automatic position function, support external printer
Defibrillation protected & Pacemaker pulse rejection function
Diagnosis analyze: ≥140 kinds
Support barcode scanner
upgradable to exercise electrocardiogram
Technical Specification:
Size and Weight | Size: 400mm×330mm×100mm(W×H×D) Weight: ≤7kg |
Display | Type: 12.1″, 800×600 TFT LCD touch screen |
Power Supply | Input voltage: AC:100V~240V, 50Hz/60Hz Input power: 100VA Standard: Comply with IEC 60601-1 and IEC 60601-1-2 |
Battery | Type: Rechargeable lithium-ion battery Rated Voltage: 11.1V Capability: 4000mAH Operating time: Used continuously for 4 hours(print 150 shares of cardiogram) Indication of battery capability: With |
Input/Output Specification | Keyboard: Standard PC 104 (position) Standard touch-screen connector (4 lines) Network connector: RJ-45 (one) TCP/IP; upgrade,Web function USB connector: 1 x USB Host Support hot-swap, external USB printer 1 x USB Device connects PC computer SD card: 1 x Standard SD card
|
Data Storage | Fixed Memory: 800 groups of ECG data Optional Memory: Flash, SD card or U disk Storage mode: Background storage automatically Storage format: PDF, DAT, Dicom, FDA-XML |
Measure and Diagnosis of ECG Waveform | HR range: 30bpm -300bpm HR precision: ±1bpm (10s average) Coefficient error: ≤5%, 0.333 Measure info of ECG waveform: P time limit, PR interphase, QRS time limit, QT interphase,QTC interphase, RV5swing, SV1swing, RV6swing, SV2swing, RV5+SV1swing, P axis, QRS axis , T axis Diagnosis analyze: ≥140 kinds |
Recorder | Recording way: Thermal dot array Horizontal resolution: 40 dots/mm Vertical resolution: 8 dots/mm Recording speed: 5 mm/s,6.25 mm/s,10 mm/s, 12.5 mm/s,25 mm/s,50 mm/s, error:±3% Record width: 215mm Paper: 210mm/215mm×20m(reel ) 210mm×140mm×20m (Z type) Paper type: Folded/Reel thermosenstive printing paper Recording type: more than 10 kind of printing methods (Auto:3×4,3×4+1R,3×4+3R,6×2,6×2+1R,12×1, 12×1_V6;Manual : 3 path, 6path, 12path, Rhythm: single-lead, three-leads , R-R: R-R)
|
Environmental Specifications | Operating: Temperature: 5℃~40℃ Relative humidity: 25%~95% (non condensing) Atmospheric pressure: 700hPa~1060hPa Transportation and storage: Temperature: -20℃~+55℃ Relative humidity: 25%~95% (non condensing) Atmospheric pressure: 500hPa~1060 hPa |