Model: CNME010709plus



Brief Introduction:
Air mode control, Set temperature and Air temperature are displayed separately;
Passive humidification;
Inclination of bassinet is adjustable;
Multiple failure alarm indications;
RS -232 connector for data output;
Oxygen input interface, Oxygen supply system;
CNME010709plus is configured with fixed Neonate Bilirubin Phototherapy Equipment which is with blue fluorescence lamps as light source, or with blue LED as light source;
Low noise DC motor.

Standard Configuration:
Based on CNME010709, plus Neonate Bilirubin Phototherapy Equipment model: (Fixed model).

Optional Configuration:
"> 37°C" temperature override mode function, Vertical height adjustment stand (VHA stand), Weighing system, Neonate Bilirubin Phototherapy Equipment (fixed model), Baby mode and SpO2.

Environmental temperature:
Operating range: 20°C- 30°C(Set temperature should be 3°C higher than the environment temperature)
Ambient air velocity: <0.3m/s

Specification:

Product name 

Air Control Mode Infant Warmer Incubator with Neonate Bilirubin Phototherapy

Power requirement

AC220V-230V/50Hz or AC110-120V/50-60Hz, 850VA

Control Mode

Air mode control

Air temperature control range

25°C-37°C(Override mode: 37°C-39°C is optional)

The temperature fluctuation range between incubator temperature and average incubator temperature (Under stable temperature condition)

≤0.5°C

Temperature Uniformity

≤0.8°C(mattress is on the horizontal position)

Inclination of the bassinet

±12°

Noise inside hood

≤45dB(A)

Failure alarm

over temperature alarm, deviation alarm,

sensor failure alarm, fan motor alarm, power failure alarm, system alarm and so on.

The average value of total irradiance for bilirubin Ebi max of phototherapy equipment

≥640 μ W/cm2

≥1300 μ W/cm2

Built-in timer range

0~9999 hrs 59min

Accuracy of weight display

±1% (equipped with weighing system)


Infant Incubator Product Packaging:

Package: The whole unit is packed into one carton
Dimension: 1085mm X 640mm X 1120mm
Gross Weight: 90Kg