Baby Care Equipment Infant Incubator with Neonate Bilirubin Phototherapy
  • Baby Care Equipment Infant Incubator with Neonate Bilirubin Phototherapy
Baby Care Equipment Infant Incubator with Neonate Bilirubin Phototherapy

Get Quotes

Download Full Catalogue

Baby Care Equipment Infant Incubator with Neonate Bilirubin Phototherapy

Model: CNME010708plus



Brief Introduction:
Two control modes: Air mode and Baby mode controlled by micro-computer;
Set temperature, Air temperature, Baby temperature are displayed separately;
Passive humidification;
Inclination of bassinet is adjustable;
Multiple failure alarm indications;
RS-232 connector for data output;
Oxygen input interface;
CNME010708plus is configured with fixed Neonate Bilirubin Phototherapy Equipment with blue
fluorescence lamp,or with blue LED as light source;
Low noise DC motor.

Standard Configuration:
Based on CNME010708, plus Neonate Bilirubin Phototherapy Equipment with Blue Light Fluorescent Tubes (Fixed model).

Optional Configuration:
"> 37°C" temperature override mode function, Vertical height adjustment stand(VHA stand), Weighing system, SpO2, Neonate Bilirubin Phototherapy Equipment with Blue LED (Fixed model), Disposable skin temperature sensor.

Environmental temperature:
Environment temperature: 20°C-30°C(Set temperature should be 3°C higher than the environment temperature)
Ambient air velocity: < 0.3m/s

Specification:

Product name 

Baby Care Equipment Infant Incubator with Neonate Bilirubin Phototherapy

Power requirement

AC220V-230V/50Hz or AC110-120V/50-60Hz, 850VA

Control Mode

Air mode and Baby mode controlled by micro-

computer

Control range of air temperature

25°C - 37°C(Override mode: 37°C-39°C is optional)

Control range of Baby temperature

34°C- -37°C(Override mode 37-38°C is optional)

Accuracy of skin temperature sensor

±0.2°C

The temperature fluctuation range between incubator temperature and average incubator temperature (Under stable temperature condition)

≤0.5°C

Uniformity of temperature

≤0.8°C(mattress is on the horizontal position)

Inclination of the bassinet

±12°

Noise inside hood

≤45dB(A)

Failure alarm

over temperature alarm, deviation alarm,

sensor failure alarm, fan motor alarm, power failure alarm, system alarm and so on.

The average value of total irradiance for bilirubin Ebi max of phototherapy equipment

≥640 μ W/cm2

≥1300 μ W/cm2

Built-in timer range

0~9999 hrs 59min

Accuracy of weight display

±1% (equipped weighing system)


Infant Incubator Product Packaging:

Package: Main body and Cabinet are packed into two cartons
Dimension (Main body): 1085mm X 640mm x 910mm
(Cabinet): 1125mm x 665mm X 725mm
Gross Weight (Main body): 75Kg
(Cabinet): 68Kg


Ask for Quote Now