Model: CNME010705


Brief Introduction:

Two control modes: Air mode and Baby mode controlled by micro- computer;

Humidity display and control system;

Oxygen concentration display system;

Set temperature, Air temperature, Baby temperature, Humidity and Oxygen are displayed separately;

“>37°C”temperature set function;

Multiple failure alarm indications;

Embedded integrated sensor box;

Integrated water reservoir in the shape of drawer;

Double wall hood, automatic air circulation device;

Inclination of bassinet is adjustable;

RS-232 connector for data output;

Low noise DC motor.

 

Standard Configuration:

Hood, Base, Mobile Cabinet, Controller, I.V pole, Tray;

 

Optional Configuration:

Fixed Neonate Bilirubin Phototherapy Equipment with blue fluorescent lamps;

Fixed Neonate Bilirubin Phototherapy Equipment with blue L ED;

Vertical height adjustment stand (VHA stand) Weighing system, Disposable skin temperature sensor and SpO2, 

 

Environmental temperature:

Operating range: 20°C~30°C(Set temperature should be 3°C higher than the environment temperature)

Ambient air velocity: <0.3m/s

 

Specification:

Product name 

Hospital Infant Incubator Equipped with Neonate Bilirubin Phototherapy Equipment

Power requirement

AC220V-230V/50Hz or AC110-120V/50-60Hz, 1000VA

Control Mode

Air mode and Baby mode controlled by micro-

computer

Air temperature control range

25°C - 37°C(Override mode 37°C-39°C)

Baby temperature control range

34°C -37°C(Override mode 37-38°C)

Accuracy of skin temperature sensor

±0.2°C

The temperature fluctuation range between incubator temperature and average incubator temperature (under stable temperature condition)

≤0.5°C

Temperature uniformity

≤0.8°C(mattress is on the horizontal position)

Inclination of the bassinet

±12°

Noise inside hood

≤45dB(A)

Failure alarm

over-temperature alarm, deviation alarm, sensor failure alarm, fan motor alarm, power failure alarm, sensor box position alarm, low water alarm, tank position alarm and system alarm

Humidity display range

0%RH~99%RH

Humidity control range

0%RH~90%RH

Accuracy of humidity display

±5%RH(environment temperature is

25°C, environment humidity is 45%RH±5%RH)

Indication range of oxygen concentration

0%~99%

Accuracy of oxygen display concentration

±2% (oxygen concentration sets ≤25%)

±3% (Oxygen concentration sets >25%)

 

Infant Incubator Product Packaging:

Package: Main body and Cabinet are packed into two cartons