Home  >  Products  >  Emergency and Clinics Apparatuses  >  Infant Incubator
Infant Care Equipment Transport Incubator for Baby
  • Infant Care Equipment Transport Incubator for Baby
Infant Care Equipment Transport Incubator for Baby

Get Quotes

Download Full Catalogue

Infant Care Equipment Transport Incubator for Baby

Model: CNME010701



Brief Introduction:

Two temperature control modes: Air mode and Baby mode controlled by micro-computer;

Use AC Power and DC Power alternatively, DC 12V or DC 24V Power on the ambulance;

Set temperature, Air temperature, Baby temperature and Internal battery capacity can be displayed separately;

Multiple failure alarm indications;

">37 °C" temperature set function as optional configuration;

Double wall acrylic glass hood with side door so that the bassinet can be pulled out from it;

Passive humidification;

The height of whole unit can be adjusted;

Oxygen supply system;

Observation lamp.

 

Standard Configuration:

Main body (Including the Hood, Controller, Bassinet, Internal battery, and Observation Lamp), Oxygen cylinders, Oxygen supply system, Skin temperature sensor, I.V. Pole, Mattress, Adjustable stand).

 

Optional Configuration:

"> 37 °C" override temperature mode, Disposable skin temperature sensor, Ambulance trolley.

 

Specification:

Product name 

Infant Care Equipment Transport Incubator for Baby

AC power requirement

AC220V- -230V/50Hz

or AC110-120V/50-60Hz, 400VA

DC Power requirement

DC12V/10A or DC24V/6A

Control Mode

Air mode and Baby mode controlled by micro-

computer

Air temperature control range

25°C - 37°C(Override mode 37°C-38°C)

Baby temperature control range

34°C- -37°C(Override mode 37-37.5°C)

Skin temperature sensor accuracy

±0.2°C

The temperature fluctuation range between incubator temperature and average incubator temperature (under stable temperature condition)

≤1.0°C

Temperature uniformity

≤1.5°C(mattress is on the horizontal position)

Noise inside hood

≤52 dB(A)

Failure alarm

over-temperature alarm, temperature deviation alarm, sensor alarm, motor fan failed alarm, power failure alarm and SO on.

Battery continuous working time

90min (Set temperature is 36°C- Ambient temperature is 15°C)


Infant Incubator Product Packaging:

Package: Main body and Cabinet are packed into two cartons

Dimension (Main body): 1090mm * 655mm * 760mm

(Cabinet): 1380mm * 610mm * 400mm

Gross Weight (Main body): 80Kg

(Cabinet): 53Kg


Ask for Quote Now

Download Our Fullcatalogue

Download Our Full Catalogue

Get notified about new products

chat online