Home  >  Products  >  Emergency and Clinics Apparatuses  >  Infant Incubator
Intensive Care Equipment Medical Infant Neonatal Incubator
  • Intensive Care Equipment Medical Infant Neonatal Incubator
Intensive Care Equipment Medical Infant Neonatal Incubator

Get Quotes

Download Full Catalogue

Intensive Care Equipment Medical Infant Neonatal Incubator

Model: CNME010704



Brief Introduction:

Two control modes: Air mode and Baby mode controlled by micro- -computer;

The information can be stored, checked and indicated by the LCD display screen;

Humidity and Oxygen concentration level display and servo control system;

“>37°C”temperature set function;

The air circulation system with outlet in both front and back;

X-ray cassette under the bassinet;

Embedded integrated sensor module, integrated water reservoir in the shape of drawer;

Inclination of bassinet is adjustable;

The height of whole unit can be adjusted;

Multiple failure alarm indications;

RS-232 connector for data output;

Low noise DC motor.

 

Standard Configuration:

Hood, Main body, Vertical height adjustment stand (VHA stand), Controller, 1.V. Pole and Shelf.

 

Optional Configuration:

Weighing system, Monitor shelf and Disposable skin temperature sensor.

 

Environmental temperature:

Operating range: 20°C~ 30°C(Set temperature should be 3°C higher than the environment temperature)

Ambient air velocity: <0.3m/s

 

Specification:

Product name 

Intensive Care Equipment Medical Infant Neonatal Incubator

Power requirement

AC220V-230V/50Hz or AC110-120V/50-60Hz, 1300VA

Control Mode

Air mode and Baby mode controlled by micro-

computer

Air temperature control range

25°C - 37°C(Override mode 37°C-39°C)

Baby temperature control range

34°C- -37°C(Override mode 37-38°C)

Accuracy of skin temperature sensor

±0.2°C

The temperature fluctuation range between incubator temperature and average incubator temperature (under stable temperature condition)

≤0.5°C

Temperature uniformity

≤0.8°C(mattress is on the horizontal position)

Inclination of the bassinet

±8°

Noise inside hood

≤45dB(A)

Failure alarm

over-temperature alarm, temperature deviation alarm, sensor alarm, motor fan failed alarm, power failure alarm, sensor box position alarm, tank position alarm, system alarm and so on.

Humidity display range

0%RH~99%RH

Humidity control range

0%RH~90%RH

Accuracy of humidity display

±5%RH(environment temperature is

25°C, environment humidity is 45%RH±5%RH)

Indication range of oxygen concentration

0%~99%

Control range of oxygen concentration

20%~60%

Accuracy of oxygen display concentration

±2% (oxygen concentration sets ≤25%)

±3% (Oxygen concentration sets >25%)

Accuracy of oxygen control concentration

±4%

Weighing Range

100- 8000g (weighing system)

Resolution for weight indication

1g (weighing system)

Accuracy of weigh

±1% (weighing system)

 

Infant Incubator Product Packaging:

Package: Main body and Cabinet are packed into two cartons

Dimension (Main body): 1110mm x 710mm x 888mm

(Cabinet): 1029mm x 697mm x 826mm

Gross Weight (Main body): 70Kg

(Cabinet): 80Kg