Get Quotes
Download Full Catalogue
Model: CNME010704
Brief Introduction:
Two control modes: Air mode and Baby mode controlled by micro- -computer;
The information can be stored, checked and indicated by the LCD display screen;
Humidity and Oxygen concentration level display and servo control system;
“>37°C”temperature set function;
The air circulation system with outlet in both front and back;
X-ray cassette under the bassinet;
Embedded integrated sensor module, integrated water reservoir in the shape of drawer;
Inclination of bassinet is adjustable;
The height of whole unit can be adjusted;
Multiple failure alarm indications;
RS-232 connector for data output;
Low noise DC motor.
Standard Configuration:
Hood, Main body, Vertical height adjustment stand (VHA stand), Controller, 1.V. Pole and Shelf.
Optional Configuration:
Weighing system, Monitor shelf and Disposable skin temperature sensor.
Environmental temperature:
Operating range: 20°C~ 30°C(Set temperature should be 3°C higher than the environment temperature)
Ambient air velocity: <0.3m/s
Specification:
Product name | Intensive Care Equipment Medical Infant Neonatal Incubator |
Power requirement | AC220V-230V/50Hz or AC110-120V/50-60Hz, 1300VA |
Control Mode | Air mode and Baby mode controlled by micro- computer |
Air temperature control range | 25°C - 37°C(Override mode 37°C-39°C) |
Baby temperature control range | 34°C- -37°C(Override mode 37-38°C) |
Accuracy of skin temperature sensor | ±0.2°C |
The temperature fluctuation range between incubator temperature and average incubator temperature (under stable temperature condition) | ≤0.5°C |
Temperature uniformity | ≤0.8°C(mattress is on the horizontal position) |
Inclination of the bassinet | ±8° |
Noise inside hood | ≤45dB(A) |
Failure alarm | over-temperature alarm, temperature deviation alarm, sensor alarm, motor fan failed alarm, power failure alarm, sensor box position alarm, tank position alarm, system alarm and so on. |
Humidity display range | 0%RH~99%RH |
Humidity control range | 0%RH~90%RH |
Accuracy of humidity display | ±5%RH(environment temperature is 25°C, environment humidity is 45%RH±5%RH) |
Indication range of oxygen concentration | 0%~99% |
Control range of oxygen concentration | 20%~60% |
Accuracy of oxygen display concentration | ±2% (oxygen concentration sets ≤25%) ±3% (Oxygen concentration sets >25%) |
Accuracy of oxygen control concentration | ±4% |
Weighing Range | 100- 8000g (weighing system) |
Resolution for weight indication | 1g (weighing system) |
Accuracy of weigh | ±1% (weighing system) |
Infant Incubator Product Packaging:
Package: Main body and Cabinet are packed into two cartons
Dimension (Main body): 1110mm x 710mm x 888mm
(Cabinet): 1029mm x 697mm x 826mm
Gross Weight (Main body): 70Kg
(Cabinet): 80Kg