Home  >  Products  >  Emergency and Clinics Apparatuses  >  Syringe Pump and Infusion Pump
Medical ambulance vet Infusion Pump for Veterinary Use
  • Medical ambulance vet Infusion Pump for Veterinary Use
Medical ambulance vet Infusion Pump for Veterinary Use

Get Quotes

Download Full Catalogue

Medical ambulance vet Infusion Pump for Veterinary Use

Model: CNME010523


Features:

Using any standard IV sets and storing up to 200 editable brands
Resetting rate, volume, air level, occlusion level without stop infusion
Infusion rates range from 0.1ml/h to 2000ml/h
Optional WIFI connection to central monitor
Last therapy for rapid infusion start
Intuitive keypad
IP44 waterproof

 

Specification:

Basic Parameters 

Case Material

PBT+PC

Screen

2.8 inch color TFT screen

Infusion Mode

ml/h (include Rate mode, Time mode), Body weight, Drip, Micro

Accuracy

±5%

Flow Rate Range

0.1-2000ml/h (min. increment 0.01 ml/h)

VTBI

0-9999.99 ml

KVO

0-5ml/h adjustable (min. increment 0.01 ml/h)

Bolus Rate

0.1-2000ml/h (programmed & manual bolus available)

Occlusion Level

4 levels selectable (150mmHg 900mmHg)

Interface

DB15 muti-functional interface

Wireless

Wifi (optional)

Alarm Type

VTBI Infused, Occlusion, Pressure drop, Battery empty, KVO finished, Standby time end, Door Open, Single air bubble, Accumulated air bubble, Abnormal drip rate, Empty drip chamber, VTBI near end, Battery near empty, Reminder alarm, No power supply, Drop sensor connection, System error, etc.

Special Features

Titration

Change flow rate without stopping infusion

Reset total volume

Reset total infused volume to zero without stopping infusion

Reset occlusion level

Reset occlusion alarm level without stopping infusion

Reset air bubble level

Reset air bubble alarm level without stopping infusion

Last Therapy

Last therapies can be stored and used for rapid infusion

Drug Library

No less than 30 drugs

Anti-Bolus

Automatic drop line pressure to reduce bolus impact after occlusion

Purge

Remove the air bubble

Screen Lock

Avoid misoperation

Standby Mode

Standby time adjustable

Micro Mode

Limit the max infusion rate to double ensure patient safety

DPS

Real-time pressure display in graphically and numerically

Bubble Detector

Adjustable. Single bubble and accumulated bubble in 15min

Brightness

Adjustable

Alarm Volume

Adjustable

History Record

More than 2000 entries

Power Source 

AC Power

110V-240V, 50/60HZ

External DC Power

10-16V

Battery

Lithium Polymer battery 2600mAh*1, more than 5 hours operating time at 25ml/h

Lithium Polymer battery 2600mAh*2, more than 10 hours operating time at 25ml/h


Ask for Quote Now

Download Our Fullcatalogue

Download Our Full Catalogue

Get notified about new products

chat online