Get Quotes
Download Full Catalogue
Model: CNME010424
Features:
10.4" TFT screen displays the ventilation parameters, alarm information, and oscillograms, make every operation more easily.
Multiple ventilation mode can meet different clinical requirements ( IPPV, A/C, SIMV, SPONT/CPAP, SIGH, MANUAL)
Multiple parameters monitoring interface, make every parameter clear for users to know patient condition in all respects.
Pressure-Time, Flow-Time oscillograms and high precision oxygen concentration detection function Included.
Humidifier can heat and wet breathing gas, makes it comfortable for patient to breathe.
Rapid oxygen supply, automatically offer high flow rate oxygen within two minutes
High temperature resistance breathing circuit is reusable and anti-pollution.
Safety:
14 types of sound and visual alarm information, easier for users to do some error checking and troubleshooting.
Easy to move with four casters, easy to stop with two brakes.
Separate design of electronic circuit and gas flow rate keep safe running of ventilator.
Compact long life internal battery can provide emergency power, avoid risk of patient.
Self-check before operation, eliminate system mistake.
Technical Specification:
Ventilation Mode | IPPV, A/C, SIMV, SPONT/CPAP, MANU |
Ventilator parameter | Tidal volume (Vt): 0, 20 ~ 1500 mL Frequency (Freq): 1min~100min I:E: 4:1~1:8 Oxygen concentration: 45%~100% PEEP: 0cmH2O ~ 20 cmH2O Pressure triggering sensitivity(Ptr): -20 cmH2O ~ 0 cmHO (Based on PEEP) SIGH: 0 (off) 1/100 ~ 5/100 Apnea ventilation: OFF, 5s~60s, |
Monitoring parameter | Frequency (Freq): 0/ min~ 100/ min Tidal volume(Vt): 0mL~2000mL MV: 0 L/min ~ 99 L/min Airway pressure: 0 cmH2O ~ 100 cmH2O Oxygen concentration: 15%~100% |
Packing size | Main components: L 560* W 560 * H 615 mm G.W. :40KG, N.W.: 17 KG Trolley: L 650* W 690 * H 520 mm G.W. : 43 KG, N.W. : 18 KG |
Alarm and protection | The AC power failure alarm: Power failure or no connection Internal backup battery low voltage alarm<11.3±0.3V No tidal volume: No tidal volume within 6 s High oxygen concentration alarm: 19%~100% Low oxygen concentration alarm: 18%~99% High airway pressure alarm: 20 cmH2O ~ 100 cmH2O Low airway pressure alarm: 0 cmH2O ~ 20 cmH2O High minute volume alarm: 1 L/min ~ 99 L/min Low minute volume alarm: 0 L/min~ 20 L/min Continuous pressure alarm: (PEEP+ 1.5 cmH2O)over16s Suffocation warning: 5~ 60s no spontaneous ventilation |
Working condition | Gas source: O2 Pressure: 280 kPa- 600 kPa Voltage: 220V±22V Power frequency: 50Hz±1 Hz Input power: 40 VA |
Oscillogram | P-T(Pressure-Time) F-T(Flow-Time) |
Navigation