Model: CNME010425
Application:
Continuous Positive Airway Pressure (CPAP) nurtures and supports infant breathing by providing respiratory support throughout the respiratory cycle.
Neo-CPAP System maintains the infant's functional residual capacity by helping to prevent airway closure.
The CNME010425 Neo-CPAP System features an ergonomic and uncluttered touch-screen interface, enabling the clinician to quickly and easy access the current patient status.
With the advantages of compact device, small footprint, saving energy and integrated high-performance in operation. This makes it an ideal companion for your smallest patients in the Neonatal Intensive Care Units (NICU), emergency ward, delivery room and other departments.
Trust Point:
10.4 Inch TFT touch LCD screen displays the ventilation parameters, alarm information and oscillogram.
Better work of breathing: Integration breathing circuit design, maximize lung protection and breathing support.
Increase clinician's confidence in Neo-CPAP: Multiple parameters monitoring interface, makes every parameter clear, let users know the patient conditions in all aspects.
Real time pressure-time oscillogram and high precision O2 concentration detection function included, reduces length of stay in hospital.
Built-in air and oxygen blender, ensures stable oxygen concentration.
Stable and low noise air compressor creates quiet work environment for doctors, can be used for 2-3 Neo-CPAP Systems together.
Technical Specification:
Ventilation Mode | CPAP, NIPPV, HFNC, MANUAL, NCPAP |
Parameter | Oxygen concentration: Adjusting range: 21% ~ 100% Monitoring range: 15% ~ 100% CPAP: Adjusting range: 0 cmH2O ~ 15 cmH2O Monitoring range: 0 cmH2O ~ 60 cmH2O Continuous flow: Adjusting range: 2 L/min ~ 20 L/min Monitoring range: 0 L/min ~ 20 L/min Pressure monitoring: 0 cmH2O ~ 60 cmH2O Inhalation pressure: 3 cmH2O ~ 15 cmH2O Exhalation pressure: 1 cmH2O~ 13 cmH2O Breath Frequency: Adjusting range: 1 /min ~ 100 /min Monitoring range: 0 ~ 100 /min Inhalation time: Adjusting range: 0.1 s~ 15s Monitoring range: 0s-15s Manual ventilation: Output flow: 20 L/min±5 L/min Air compressor: Continuous output flow: ≥25 L/min Peak output flow: ≥120 L/min |
Oscillogram | P-T (pressure-time) Flow of oxygen, air and mixed gas Airway pressure oscillogram |
Alarm and protection | The AC power failure alarm: Power failure or no connection Internal backup battery low voltage alarm<11.3±0.3V High oxygen concentration alarm: 19%~100% Low oxygen concentration alarm: 15%~99% High airway pressure alarm: 1.5kPa~6kPa Low air input pressure alarm: < 200 kPa Low oxygen input pressure alarm: < 200 kPa Air and oxygen blender alarm: When any gas source lack When differential pressure: > 0.1m Pa Compression pump alarm: Excess temperature |
Working condition | Gas source: O2, Air Pressure: 280 kPa- 600 kPa Voltage: 100~240V Power frequency: 50Hz±1 Hz |
Wooden case packing size | Main components: L683*W687*H1140 mm G.W..105 KG, NW.: 70 KG Air compressor: L505*W566* H615 mm G.W. : 43 KG N.W. : 22 KG |