CPAP System 10.4 Inch LCD Touch Screen Neonatal Ventilator Apparatus
  • CPAP System 10.4 Inch LCD Touch Screen Neonatal Ventilator Apparatus
CPAP System 10.4 Inch LCD Touch Screen Neonatal Ventilator Apparatus

Get Quotes

Download Full Catalogue

CPAP System 10.4 Inch LCD Touch Screen Neonatal Ventilator Apparatus

Model: CNME010425

Application:

Continuous Positive Airway Pressure (CPAP) nurtures and supports infant breathing by providing respiratory support throughout the respiratory cycle.

Neo-CPAP System maintains the infant's functional residual capacity by helping to prevent airway closure.

The CNME010425 Neo-CPAP System features an ergonomic and uncluttered touch-screen interface, enabling the clinician to quickly and easy access the current patient status.

With the advantages of compact device, small footprint, saving energy and integrated high-performance in operation. This makes it an ideal companion for your smallest patients in the Neonatal Intensive Care Units (NICU), emergency ward, delivery room and other departments.

 

Trust Point:

10.4 Inch TFT touch LCD screen displays the ventilation parameters, alarm information and oscillogram.

Better work of breathing: Integration breathing circuit design, maximize lung protection and breathing support.

Increase clinician's confidence in Neo-CPAP: Multiple parameters monitoring interface, makes every parameter clear, let users know the patient conditions in all aspects.

Real time pressure-time oscillogram and high precision O2 concentration detection function included, reduces length of stay in hospital.

Built-in air and oxygen blender, ensures stable oxygen concentration.

Stable and low noise air compressor creates quiet work environment for doctors, can be used for 2-3 Neo-CPAP Systems together.


Technical Specification:

Ventilation Mode

CPAP, NIPPV, HFNC, MANUAL, NCPAP

Parameter

Oxygen concentration:

Adjusting range: 21% ~ 100%

Monitoring range: 15% ~ 100%

CPAP:

Adjusting range: 0 cmH2O ~ 15 cmH2O

Monitoring range: 0 cmH2O ~ 60 cmH2O

Continuous flow:

Adjusting range: 2 L/min ~ 20 L/min

Monitoring range: 0 L/min ~ 20 L/min

Pressure monitoring: 0 cmH2O ~ 60 cmH2O

Inhalation pressure: 3 cmH2O ~ 15 cmH2O

Exhalation pressure: 1 cmH2O~ 13 cmH2O

Breath Frequency:

Adjusting range: 1 /min ~ 100 /min

Monitoring range: 0 ~ 100 /min

Inhalation time:

Adjusting range: 0.1 s~ 15s

Monitoring range: 0s-15s

Manual ventilation: Output flow: 20 L/min±5 L/min

Air compressor:

Continuous output flow: ≥25 L/min

Peak output flow: ≥120 L/min

Oscillogram

P-T (pressure-time)

Flow of oxygen, air and mixed gas

Airway pressure oscillogram

Alarm and protection

The AC power failure alarm: Power failure or no connection

Internal backup battery low voltage alarm<11.3±0.3V

High oxygen concentration alarm: 19%~100%

Low oxygen concentration alarm: 15%~99%

High airway pressure alarm: 1.5kPa~6kPa

Low air input pressure alarm: < 200 kPa

Low oxygen input pressure alarm: < 200 kPa

Air and oxygen blender alarm: When any gas source lack

When differential pressure: > 0.1m Pa

Compression pump alarm: Excess temperature

Working condition

Gas source: O2, Air

Pressure: 280 kPa- 600 kPa

Voltage: 100~240V

Power frequency: 50Hz±1 Hz

Wooden case packing size

Main components: L683*W687*H1140 mm

G.W..105 KG, NW.: 70 KG

Air compressor: L505*W566* H615 mm

G.W. : 43 KG

N.W. : 22 KG 