Model: CNME010401


Technical Specification:

Ventilation Modes

VCV(A/C) PCV(A/C) PRVC SIMVIVCV)+PSV

SIMV(POV)+PSV SIMV(PRVC)+PSV SPONT/CPAP+PSV BIVENT+PSV NIV/CPAP NIV-T NIV-S/T

Parameters

Tidal Volume: 20-2000 ml

Respiration Rate: 1-80 bpm

Tinsp: 0.2~9 s

Tslope: 0-2 s

Tpause: 0~4 s

I:E Ratio: 1:10-4:1

FiO2: 21 %~100%

Trigger Sensitivity: Pressure (-20~0 cmH2O, above PEEP)

Flow (0.5~20 LPM)

PEEP: 0~35 omH2O

Psupport: 0~70 omH2O

Pinsp: 5~70 omH2O

Special Procedures

Apnea Ventilation Smart Suction Manual Breath

Insp/ Exp Hold ETCO2 Measurement

Nebulization Waveform Freeze

Monitoring

Pressure Value: Ppeak, Pplat, Pmean, Pmin, PEEP

Volume / Flow Value: Vti, Vte, MV, MVspont

Time Value: ftotal, fspont, l:E

Real Time Curves: Pressure-Time, Flow-Time, Volume-Time waveforms

Pressure-Volume, Volume-Flow, Flow-Pressure loops

Gas Monitoring: FiO2, ETCO2

Calculated Values: Compliance(C)

Resistance(B)

MVleak

RSBI

WOB

PEEPi

Alarm

Paw high/low MVe high/low Circuit disconnection

FiO2 high/low Inspiration/Expiratory tidal volume low

High Respiration Rate Apnea AC Failure Nebulizer On

Low Battery Air/O2 supply down High/Low PEEP

Leakage out of range Occlusion

Technical Data

Screen: 12”TFT color touch screen (detachable)

Supply Gas: O2, 0.28~0.6 MPa

Power Supply: AC100~240 V, 50 Hz/60 Hz

Communication Interface:  RS-232 Port, Nurse call Port, Ethernet Port

Dimension (WxDxH):

322 mm x 375 mm x 366 mm (Main Unit)

547mmx675mmx950mm(Cart)

Weight: 12.5 kg (Main Unit)

25 kg (Cart)


Superior Mobile ICU ventilator

Comprehensive ICU ventilator including BIVENT and PRVC

Compact, big capacity battery, no air compressor, intra-hospital mobility

Flexible device configuration: equipped on a trolley, bed or ceiling pendant

Cost Effective Solution

Unique metal-based, autoclaved, heated exhalation valve

Built-in flow sensor, non-consumable design

Upgradeable ventilation system software, with an available USB port

 

Safe Ventilation Through Whole Treatment Phase

Initial Treatment Phase

Noninvasive ventilation mode associated with decrease incubation rates, shortened patient stays, improved patient comfort, and a reduced risk of cross infection

Preset patient's height and IBW. Reduce clinician's workload

Stable Condition Phase

PRVC and BIVENT employ lung-protective strategies, delivering intelligent ventilation

Comprehensive lung mechanics monitoring include compliance, airway resistance, PEEPi and time constant

Three waveforms & three loops with user-friendly display provide a continuous monitoring of the patient's condition

Weaning Phase

Various ventilation modes enhance the weaning process

The unique trigger and leakage compensation system safeguards each and every patient breath resulting in smooth and comfortable breathing, avoiding extra workload on the patient and promoting recovery

RSBI and WOB provide accurate reference for weaning

Rehab Phase

Data export port provides connection to hospital monitors and Patient Data Management Systems

Provides pressure support for the patient when spontaneous breathing is present

 

An Optimal Combination of Invasive and Noninvasive Ventilator

As noninvasive ventilation is used increasingly in a wide range of clinical situations, we offer a dual solution

CNME010401 combines the advantages of a flexible noninvasive ventilator with a full-featured invasive ventilator for the ICU

 

Optimal patient-ventilator synchrony, increase patient comfort

The Unique Leak Compensation System - Keep precise control on the tidal volume of each breath

delivered to the patient by adjusting compensation dosage automatically

Advanced Trigger Technique - Enhance sensitivity, avoid spurious triggering

 

Auto-detect and Adjust Leak Compensation

Automatically, Adapt to Patient’s Breathing Pattern

Multi-parameter Monitoring 