Home  >  Products  >  Emergency and Clinics Apparatuses  >  Ventilator
Multi-functional High Performance Ventilator
  • Multi-functional High Performance Ventilator
Multi-functional High Performance Ventilator

Get Quotes

Download Full Catalogue

Multi-functional High Performance Ventilator

Model: CNME010408

Description:

20-2000ml (VCV); Applicable to adult, pediatric and infant

Various ventilation modes for different needs of all patients

10.1 inch TFT touch screen with big font view for easy observation

Touch screen(optional)

Navigation knob for simple operation

Simultaneous display of 3 waveforms and 2 loops

Synchronized nebulizer (optional)

Low noise and water-free medical air compressor (optional)

Expiratory valve could be taken off for autocalvable disinfection to avoid cross-infection

Active exhalation valve with anti condensation design

World leading brands of key components of ventilator ensure high accuracy and stable performance.

Advanced proportional solenoid technology realize accurate ventilation control

Multi-safety mechanism and three-priority alarm of visual and audio for different risks

 

Technical Data:

Specification:


Patient type

Adult, Pediatric and infant (≥5kg)

Ventilation modes

VCV, PCV, SIMV(V)+ PS, SIMV(P)+ PS, SPONT/CPAP, Sigh, Standby

Optional: PRVC, Dual PAP, NPPV,

Tidal Volume

20- 2000 mL

Ventilation frequency

1- 100 bpm

Inspiration time

0.1-10S (increment:0.1S)

FiO2

21 %- 100%

Flow trigger

0.5-20L/Min

Pressure trigger

-20-0cmH2O

Pressure control

5-70 cm H2O

Pressure support

0-70 cm H2O

Electronic PEEP

0-50 cm H2O (increment: 1 cm H2O)

Nebulizer(optional)

30 minutes

Direct access function

Freeze, Lock

Monitoring

Volume:Vti,Vte, MV, MVspont. Pressure:Ppeak, Pmean, Pplat, Pmin, PEEP, Freq

Fspont, I:E, FiO2, Compliance, Resistance, RSB, P0.1, NIF, Auto PEEP, Rcexp, Cdyn

Waveform

P-T, F-T, V-T

Loop

P-V, F-V, F-P

Trend

Peak, FiO2, PEEP, MV, Vte, Vti

System Log

500 events (setting and alarm)

Alarm

Audio and visual alarms with three levels

Volumes: Vte high/low, MV high/low; Pressure: Paw high/low

O2 supply pressure high/low, Air supply pressure high/low

Apnea, Continuous high airway pressure

Freq high/low, FiO2 high/low

Power: AC power failure, Low battery power, Exhausted battery failure

Physical Specification


Dimensions (HxWxD)

Host:631*725*605(mm) Trolley:225*805*555(mm)

Communication Interface

RS232

Screen

10.1 inch TFT screen

Net weight

Host:42kg,Trolley:22.5kg

Power

100- 240VAC, 50/60Hz, 1A(Max)

Lithium Battery

Minimum 120 minutes


Ask for Quote Now

Download Our Fullcatalogue

Download Our Full Catalogue

Get notified about new products

chat online