Home  >  Products  >  Emergency and Clinics Apparatuses  >  Infant Incubator
Hospital Infant Care Equipment Neonatal Incubator for Babies
  • Hospital Infant Care Equipment Neonatal Incubator for Babies
Hospital Infant Care Equipment Neonatal Incubator for Babies

Get Quotes

Download Full Catalogue

Hospital Infant Care Equipment Neonatal Incubator for Babies

Model: CNME010708



Brief Introduction:
Two control modes: Air mode and Baby mode controlled by micro-computer;
Set temperature, Air temperature, Baby temperature are displayed separately;
Passive humidification;
Inclination of bassinet is adjustable;
Multiple failure alarm indications;
RS-232 connector for data output;
Oxygen input interface;
Low noise DC motor.

Standard Configuration:
Main body, Cabinet, Temperature Controller, Hood, I.V. pole, Tray.

Optional Configuration:
"> 37°C" temperature override mode function, Vertical height adjustment stand(VHA stand), Weighing system, SpO2, Neonate Bilirubin Phototherapy Equipment with Blue LED (Fixed model), Disposable skin temperature sensor.

Environmental temperature:
Environment temperature: 20°C-30°C(Set temperature should be 3°C higher than the environment temperature)
Ambient air velocity: < 0.3m/s

Specification:

Product name 

Hospital Infant Care Equipment Neonatal Incubator for Babies

Power requirement

AC220V-230V/50Hz or AC110-120V/50-60Hz, 850VA

Control Mode

Air mode and Baby mode controlled by micro-

computer

Control range of air temperature

25°C - 37°C(Override mode: 37°C-39°C is optional)

Control range of Baby temperature

34°C- -37°C(Override mode 37-38°C is optional)

Accuracy of skin temperature sensor

±0.2°C

The temperature fluctuation range between incubator temperature and average incubator temperature (Under stable temperature condition)

≤0.5°C

Uniformity of temperature

≤0.8°C(mattress is on the horizontal position)

Inclination of the bassinet

±12°

Noise inside hood

≤45dB(A)

Failure alarm

over temperature alarm, deviation alarm,

sensor failure alarm, fan motor alarm, power failure alarm, system alarm and so on.

The average value of total irradiance for bilirubin Ebi max of phototherapy equipment

≥640 μ W/cm2

≥1300 μ W/cm2

Built-in timer range

0~9999 hrs 59min

Accuracy of weight display

±1% (equipped weighing system)


Infant Incubator Product Packaging:

Package: Main body and Cabinet are packed into two cartons
Dimension (Main body): 1085mm X 640mm x 910mm
(Cabinet): 1125mm x 665mm X 725mm
Gross Weight (Main body): 63Kg
(Cabinet): 68Kg


Ask for Quote Now

Download Our Fullcatalogue

Download Our Full Catalogue

Get notified about new products

chat online