Model: CNME010311

Description:
20-1500ml (VCV); Applicable to adult, pediatric, infant
Various modes for different needs of all patients
Anesthesia Agent, CO2 and SpO2 monitoring modules (optional)
10.1 inch TFT screen & big font view for easy observation
Touch screen (optional)
Electronic flowmeters for O2, N2O, Air. High accuracy and easy reading
Highly integrated absorber, autoclavable in 134°C to avoid cross-infection (optional)
The absorber could be automatically heated, to avoid water condensation (optional)
Electronic PEEP
Advanced proportional solenoid technology to realize accurate ventilation control
Auxiliary oxygen flowmeter (optional)
Active AGSS system deal with exhaust gas and reduce pollution, providing more safety protection (optional)
Sliding writing table
Compact design, cute and space saving


Technical Specification:

Specification
 
 
Ventilation modes: VCV, PCV, SIMV(V)+ PS, SIMV(P)+PS, Spont(optional), Manual, Standby
Tidal Volume: 20-1500mL
Ventilation frequency: 4-60bpm
I:E: 3:1-1:6(increment: 0.5)
Ti: 0.1-10s(increment: 0.1s)
Inspiratory pause(Tp): OFF, 5%-50%
Flow Trigger: 1-15L/min
Pressure control: 5-70 cmH2O
Pressure support: 5-60 cmH2O
Pressure limited: PEEP+5-PEEP+ 70 cm H20
Electronic PEEP: OFF, 4-30 cm H2O
Monitoring
Volume: VTI, VTE, MV, MVspont
Pressure: Ppeak, PEEP, Pplat, Pmean, Pmin
Freq, Fspont, I:E, Compliance, Resistance, FiO2
SpO2 Module (optional): SpO2, PR
CO2 Module (optional): EtCO2, FiCO2
Anesthetic Agent Module (optional): Anesthetic agent, N2O, CO2, and MACAge
Waveform: P-T, F-T, V-T
Loop: P-V, F-V, F-P, Optional: Volume-EtCO2
Trend:
Ppeak, FiO2, MV, PEEP, VTE
Alarm: .
Audio and visual alarms with three levels
Volume: MV high/low, VTE high/low
Pressure: Paw high/low, Negative pressure, Low O2 supply pressure Apnea, Continuous high airway pressure
Freq high/low, FiO2 high/low, EtCO2 high/low (optional), SpO2 low (optional)
Power: AC power failure, Low battery power, Exhausted battery failure
Vaporizer2 stations with interlock (Selectatec compatible)
Agent type: Halothane, Enflurane, Isoflurane, Sevoflurane
Filler type: Pour fill, Quik fil(only Sevoflurane)
Pneumatic SpecificationGas supply: O2, N2O, Air: 0.28-0.6 Mpa
Electronic Flowmeter: O2/N2O/Air: 0-l0L/Min
Gas system: O2 deficiency alarm. Hypoxic guard system, O2 flush: 35-75L/Min
Working mode: Closed, Semi-closed, Semi-open, Open
Driven mode: Pneumatically driven and electronically controlled
Operating mode: Manual/Vent
Physical SpecificationDimensions (HxWxD): 1510*1000*700(mm)
Communication Interface: RS232
Screen: 10.1 inch TFT screen
Net weight: 85 kg
Power: 100-240VAC, 50/60Hz,6.5A(Max)
Lithium Battery: Minimum 120 minutes