Get Quotes
Download Full Catalogue
Model: CNME040106
Description:
Be applicable of hemodialysis treatment,hemoperfusion,Plasma Exchange,Pure UF treatments; touch screen display, with Na+ and UF profiles, backup power supply, Kt/V, HCO3- adjustment, single needle, acetate treatment.
Clinical Application
Hemodialysis therapy.
Mainly suitable for all kinds of acute and chronic kidney failure patient
Pure ultrafiltration therapy
Mainly suitable for patients with excessive water stored in the body due to acute, chronic kidney failure or incomplete heart function
Hemoperfusion therapy
Mainly applies in the acute drug poisoning, especially those accompanied by the brain function barrier or stuper, liver and kidney function barrier, old patients and those who takes medicine oversized which had achieved the to xicant lethal dose density or exceed 30% of their own elimination ability
Plasma exchange therapy
Mainly suitable for the immunity diseases; acute nephritis, lupous nephritis, frequent myeloma nephrosis, serious myasthenia, acute liver function failure, thyroid gland crisis, ethnic hypercholesterolemia, HVS etc.
Feature
Bicarb Dry Powder cartridge.
Producing bicarbonate dialysis solution on line to reach a pure and full-complete dialysis treatment.
Na+ and UF profiling
Be applicable for reducing the cases during dialysis treatment such as low/high pressure, muscle convulsion, headache, nausea, vomit and the occurance rate of high pressure after dialysis treatment etc
Kt/V function
The sufficiency of dialysis can be reflected by Kt/V
HCO3 adjustment
Be applicable for sericous acid toxicosis patient.
Be capable to calibrate the acid toxicosis status according to patient's state of illness
Pyrogen filter port: (optional)
Completely filtrating the remained bacteria and endotoxin
Network connection:(optional)
One computer can audit and control the treatment of maximum 20 units hemodialysis machine
Technical Parameters:
Volume:(length*width*height) | 370mm*340mm*1420mm |
Weight | About 90kg |
Power supply voltage | AC220V±10% AC110V(optional) |
Frequency | 50HZ ~ 60 HZ |
Power | 1500W Blood pump/spare pump |
Flux | 15-340m/min(φ6mm) 20 ~ 620 ml/min (φ8mm) Heparin pump |
Flux | 0. 1m/h~ 10ml/h(±5%) |
Precise | 0.1 ml/h |
Injector size | 10m/20ml/30ml 20m/30ml/50ml(optional) Arterial pressure |
Display scope | -300mmHg~+ 300mmHg (±10mmHg) Venous pressure |
Display scope | -50mmHg~ + 300mmHg (±10mmHg) Dialysate Flow |
300m/min-800m/min linearity adjustable (+10%) (-5%) | |
Temperature | 35.0 ~39.0 |
Resolving rate | 0.1 |
Conductivity | 13mS/cm~ 15.5mS/cm (±0.1 mS/cm) |
UF flow scope | 0-4000ml/h |
ISO UF flow scope | 0~2000ml/h(±30m/h) |
TMP Scope | -100mmHg~+ 600mmHg (±20mmHg) |
Blood leakage monitor | over 1ml blood per liter dialysae(flow:500ml/min) |
Blood level monitor | ultrasonic sensor Air bubble monitor |
Infrared and response threshold value:Single air bubble of 2004 exists when Blood flux is 200ml/min | |
Inflow pressure | 0MPa-0.6MPa |
Inflow temperature | 5 ~30ºC |
Environment temperature | 10 ~30ºC |
Relative humidity | ≤70% |
Rinse/disinfection | chemical disinfection (citric acid, peracetic acid and sodium hypochlorite) |
Hot rinse | 90ºC |
Back-up power supply | last for 15-30min after electric-cut |