Home  >  Products  >  Hemodialysis System  >  Dialysis machine
Portable Medical Mobile Hemodialysis Machine Kidney Dialysis Machine
  • Portable Medical Mobile Hemodialysis Machine Kidney Dialysis Machine
  • Portable Medical Mobile Hemodialysis Machine Kidney Dialysis Machine
Portable Medical Mobile Hemodialysis Machine Kidney Dialysis MachinePortable Medical Mobile Hemodialysis Machine Kidney Dialysis Machine

Get Quotes

Download Full Catalogue

Portable Medical Mobile Hemodialysis Machine Kidney Dialysis Machine

Model: CNME040106

Description:
Be applicable of hemodialysis treatment,hemoperfusion,Plasma Exchange,Pure UF treatments; touch screen display, with Na+ and UF profiles, backup power supply, Kt/V, HCO3- adjustment, single needle, acetate treatment.


Clinical Application
Hemodialysis therapy.
Mainly suitable for all kinds of acute and chronic kidney failure patient
Pure ultrafiltration therapy
Mainly suitable for patients with excessive water stored in the body due to acute, chronic kidney failure or incomplete heart function
Hemoperfusion therapy
Mainly applies in the acute drug poisoning, especially those accompanied by the brain function barrier or stuper, liver and kidney function barrier, old patients and those who takes medicine oversized which had achieved the to xicant lethal dose density or exceed 30% of their own elimination ability
Plasma exchange therapy
Mainly suitable for the immunity diseases; acute nephritis, lupous nephritis, frequent myeloma nephrosis, serious myasthenia, acute liver function failure, thyroid gland crisis, ethnic hypercholesterolemia, HVS etc.

Feature
Bicarb Dry Powder cartridge.
Producing bicarbonate dialysis solution on line to reach a pure and full-complete dialysis treatment.
Na+ and UF profiling
Be applicable for reducing the cases during dialysis treatment such as low/high pressure, muscle convulsion, headache, nausea, vomit and the occurance rate of high pressure after dialysis treatment etc
Kt/V function
The sufficiency of dialysis can be reflected by Kt/V
HCO3 adjustment
Be applicable for sericous acid toxicosis patient.
Be capable to calibrate the acid toxicosis status according to patient's state of illness
Pyrogen filter port: (optional)
Completely filtrating the remained bacteria and endotoxin
Network connection:(optional)
One computer can audit and control the treatment of maximum 20 units hemodialysis machine



Technical Parameters:

Volume:(length*width*height)370mm*340mm*1420mm
WeightAbout 90kg
Power supply voltageAC220V±10%
AC110V(optional)
Frequency50HZ ~ 60 HZ
Power1500W
Blood pump/spare pump
Flux15-340m/min(φ6mm)
20 ~ 620 ml/min (φ8mm)
Heparin pump
Flux0. 1m/h~ 10ml/h(±5%)
Precise0.1 ml/h
Injector size10m/20ml/30ml
20m/30ml/50ml(optional)
Arterial pressure
Display scope-300mmHg~+ 300mmHg
(±10mmHg)
Venous pressure
Display scope-50mmHg~ + 300mmHg
(±10mmHg)
Dialysate Flow
300m/min-800m/min linearity adjustable
(+10%) (-5%)

Temperature35.0 ~39.0
Resolving rate0.1
Conductivity13mS/cm~ 15.5mS/cm
(±0.1 mS/cm)
UF flow scope0-4000ml/h
ISO UF flow scope0~2000ml/h(±30m/h)
TMP Scope -100mmHg~+ 600mmHg
(±20mmHg)
Blood leakage monitorover 1ml blood per liter dialysae(flow:500ml/min)
Blood level monitorultrasonic sensor
Air bubble monitor
Infrared and response threshold value:Single air bubble of
2004 exists when Blood flux is 200ml/min

Inflow pressure0MPa-0.6MPa
Inflow temperature5 ~30ºC
Environment temperature10 ~30ºC
Relative humidity≤70%
Rinse/disinfectionchemical disinfection
(citric acid, peracetic acid and sodium hypochlorite)
Hot rinse90ºC
Back-up power supplylast for 15-30min after
electric-cut


Ask for Quote Now

Download Our Fullcatalogue

Download Our Full Catalogue

Get notified about new products

chat online