Model: CNME010511


Technical Specification:

Component

Description

Product name

3.5 Inch Large Touch Screen Multi Channel Syringe Pump with Advanced Modular Design

Infusion rates

5/6ml syringes - 0.1 -150 ml/h
10ml syringes - 0.1 -300 ml/h
20ml syringes - 0.1 -600 ml/h

30ml syringes - 0.1-800 ml/h

50/60ml syringes - 0.1 -1500 ml/h

Bolus rates

5/6ml syringes - 0.1 -150 ml/h
10ml syringes - 0.1 -300 ml/h
20ml syringes - 0.1 -600 ml/h

30ml syringes - 0.1-800 ml/h

50/60ml syringes - 0.1 -1500 ml/h

Purge rates

5/6ml syringes - 0.1 -150 ml/h
10ml syringes - 0.1 -300 ml/h
20ml syringes - 0.1 -600 ml/h

30ml syringes - 0.1-800 ml/h

50/60ml syringes - 0.1 -1500 ml/h

Syringe sizes

5/6ml, 10ml, 20ml, 30ml, 50/60ml of all major brands including additional brands upon agreement. Build-in 35 syringes types, user-defined 10 syringe types

Dose rate units

No less than 50 types of units to be chose. mg/kg/min, mg/kg/h, mg/kg/24h,...

Bolus volume limit

0.1ml -50ml in steps of 0.1ml/h

Purge volume

Pipe flush rate is consistent with manual fast push rate,
the Vol. is 0.5ml, 1ml, 1.5ml, 2ml

Volumetric accuracy

±2%

Volume To Be Infused (VTBI)

0.1-99.99 ml, 0.01ml;
100.0-999.9 ml, 0.1ml;
1000-9999 ml, 1ml;
Cumulated volume range: 0.01-9999.99ml

Programmable infusion time

Preset time: 00:00:01-99:59:59 (h:m:s)

Keep Vein Open (KVO) rate

0.1~5.0 ml/h, step value 0.01ml.

KVO volume

1%, 2%, 3% of the syringe volume

Post VTBI rate

Stop, KVO mode or continue with the set rate

Infusion mode

Rate mode, Dosage mode,Preset time mode (V-T), Time mode (R-T), Relay mode, Trapezia mode, Intermittent mode, Loading Dose mode, Sequence mode.

Event log

more than 2000. classified by operation records, alarm
records, and infusion records. time stamped in real time

Patient history log

No less than 2000 logs

Drug library

2000 cases

Brightness

9 levels

Interfaces

-USB
-Nurse call
-RS232
-WIFI(optional)



Ask for Quote Now