Product Brief Introduction:

CNME-1200 infusion pump is the second generation product. It has LCD display and micro computer controller. The peristaltic pump is power source with multiple sensors to monitor the infusion pump and has variety of alarm functions. It's easy to operate and meets all the demand of various cases of infusion.

There are two infusion channels, it can work the two channels simultaneously, also can work with one of the two.

Product Function:

Automatic infusion: Set the infusion volume and speed. The peristaltic pump which is microcomputer controlled will automatic infusion according to the setting infusion speed.

KVO status: After finishing the total volume of infusion, the pump will switch to KVO status automatically.(keep vein open status).

Audible and visual alarm: Occlusion alarm, Bubble alarms, Door Open alarm, Infusion Finished alarm and Under-voltage alarm.

Suitable IV set:

Ordinary IV set: Normal PVC titration IV set or lucifuge IV set(pipe diameter is about 3.5mm)

Make sure the pipe wall of IV set must have elasticity coefficient, before using the new brands IV set should be calibrated.

Note: Other specifications of the IV set may not be able to maintain accuracy (even if the precision was calibrated) Special IV set: special IV set using  high elastic silicone tube, please contact our company for purchasing.

AC and DC power supply:

Built in Li-ion rechargeable battery pack, when AC power is off, system will switch to battery power supply immediately. when battery volume is insufficient the charging will automatically start, when battery volume is full the charging will automatically stop(it may take 7 hours).

Bolus mode:

Press the bolus key twice quickly and enter into bolus mode, when infusion pump is not infusion, the bolus liquid will not be counted into infused volume, when infusion pump is infusion, the bolus liquid will be counted into infused volume. Until release the bolus key the bolus mode will stop.

Infusion Rate:

It has two infusion rate modes: drop/min and ml/h. Note: drop/min and ml/h is conversed by 20 drops/ml, which is different from the actual IV set.

Technical Specification:

Infusion rate:

Special IV set: 0.1ml/h~1200ml/h

Ordinary IV set: 0.1ml/h~600ml/h

Note: with 0.1-30ml/h(0.1ml/h/step)

Over 30ml/h(1ml/h/step)

Infusion precision:

Special IV set: ±5%(medium speed, 23℃,humidity:60%);

Ordinary IV set: ±10%(medium speed, 23℃,humidity:60%);

Total infusion volume preset: 0.1~9999ml.

Remarks: with 0.1-30ml(0.1ml/step);

         Over 30ml(1ml/step).

Occlusion sensitivity: It has three adjustable levels of occlusion pressure as high, medium and low.

Low speed (1ml/h): 250-500 seconds;

Medium speed(120ml/h): 7~14 seconds;

High speed(600ml/h): 0.2~1 seconds.

Above data is measured at the status of  25℃ ambient temperature, ordinary pressure, use ordinary PVC infusion apparatus and high sensitivity.

KVO: 1-2ml/H

Power supply:

AC: 100~240V, 50/60Hz

DC: 11.1V(built in battery), 2200mAh

Fuse: F0.75AL(socket back).

Power consumption: 30VA

Built in battery work time:

Battery can continuous work about 3 hours at full capacity and medium flow rate(25ml/h), the work time is related to rate. Within the battery normal life it could charge and discharge about 500 times.

Working condition:

Environmental temperature: +5℃~+40℃

Relative humidity: 20%-90%

Product dimension and weight: 185*115*196(mm), 3.8kg.

Security classification:

Class I BF, IPX1;

Please keep the infusion pump away from strong electromagnetic equipment, for example: radio knife, MRI.